Detail HEIDENHAIN LC 405 Funtional Safety
Specifications LC 415
Measuring standard
Coefficient of linear expansion
DIADUR glass scale with absolute track and incremental track, grating period 20 µ m
± therm H 8 x 10-6 K-1, ( mounting type I / II) ; with mounting spar: ± therm H 9 x 10-6 K-1
Accuracy grade*
± 3 µ m; ± 5 µ m
Measuring length ML* in mm
Mounting spar* or clamping elements* up to ML = 1240 optional, necessary as of ML 1340
70, 120, 170, 220, 270, 320, 370, 420, 470, 520, 570, 620, 670, 720,
770, 820, 920, 1020, 1140, 1240, 1340, 1440, 1540, 1640, 1740, 1840, 2040
Functional safety
For applications up to
SIL 2 according to EN 61 508 ( further basis for testing: EN 61 800-5-2)
Category 3, PL “ d” according to EN ISO 13 849-1: 2008
PFH
d 15 x 10– 9 ( probability of dangerous failure per hour)
Safe position1)
Encoder: ± 550 µ m ( safety-related measuring step: SM = 220 µ m)
Mechanical connection: fault exclusions for loosening of the housing and scanning unit ( page 6)
Absolute position values
EnDat 2.2
Ordering designation
EnDat 22
Resolution
Accuracy ± 3 µ m: 0.001 µ m, accuracy ± 5 µ m: 0.010 µ m
Clock frequency
d 16 MHz
Calculation time tcal
d 5 µ s
Electrical connection
Separate adapter cable connectable to mounting block
Cable length
d 100 m ( with HEIDENHAIN cable) , clock frequency d 8 MHz
Power supply
3.6 to 14 V DC
Power consumption ( max.)
At 14 V: d 1.3 W; at 3.6 V: d 1.1 W
Power consumption ( typical)
At 5 V: 0.7 W ( without load)
Traversing speed
d 180 m/ min
Required moving force
d 5 N
Vibration 55 to 2 000 Hz
affecting the
Shock 11 ms
Acceleration
Scanning unit: d 200 m/ s2 ( EN 60 068-2-6)
Housing without mounting spar: d 100 m/ s2 ( EN 60 068-2-6)
Housing with mounting spar and cable outlet at right: d 150 m/ s2, at left: d 100 m/ s2 ( EN 60 068-2-6)
d 300 m/ s2 ( EN 60 068-2-27)
d 100 m/ s2 in measuring direction
Operating temperature
0 ° C to 50 ° C
Protection EN 60 5292)
IP 53 when installed according to instructions in the brochure, IP 64 with sealing air from DA 400
Weight
Encoder: 0.2 kg + 0.55 kg/ m measuring length; mounting spar: 0.9 kg/ m
* Please select when ordering
1) Further tolerances may occur in the subsequent electronics after the position value comparison ( contact the manufacturer of the subsequent electronics) / 2) In the application the LC must be protected from the intrusion of particles and liquids
Mounting type I = End block 12A; for mounting with and without mounting spar
ANOTHER TYPE
= = = = = = = = = =
LC 405 , LC 403-Predecessor , LC 105 - Functional Safety
LC 105 , LC 103-Predecessor , LC 200
LC 103 , LC 200 , LF 485 , LF 185 , LS 400
LS 100 , LB 382 - Single - Section
LB 382 - Multi Section
= = = = = = = = = = = = = = = = =
Call : PT DWI SUBUR MAKMUR
Jakarta- Indonesia
Telp ; 021 47869642 , 47881968, 479101
fax : 021 4719009
Email : dsm@ @ indo.net.id
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Tampilkan Lebih Banyak