Detail HEIDENHAIN LC 105-Functional Safety
Specifications LC 115
Measuring standard
Coefficient of linear expansion
DIADUR glass scale with absolute track and incremental track, grating period 20 µ m
± therm H 8 x 10-6 K-1
Accuracy grade* ± 3 µ m up to measuring length 3040 mm; ± 5 µ m
Measuring length ML* in mm
140, 240, 340, 440, 540, 640, 740, 840, 940, 1040, 1140, 1240, 1340, 1440,
1540, 1640, 1740, 1840, 2040, 2240, 2440, 2640, 2840, 3040, 3240, 3440, 3640, 3840,
4040, 4240
Functional safety For applications up to
SIL 2 according to EN 61 508 ( further basis for testing: EN 61 800-5-2)
Category 3, PL “ d” according to EN ISO 13 849-1: 2008 PFH
d 15 x 10– 9; ML > 3 040: 25 x 10– 9 ( probability of dangerous failure per hour)
Safe position1)
Encoder: ± 550 µ m; ML > 3 040: ± 2 050 µ m ( safety-related measuring stap: SM = 220 µ m)
Mechanical connection: fault exclusions for loosening of the housing and scanning unit ( page 6)
Absolute position values
EnDat 2.2
Ordering designation
EnDat 22
Resolution
Accuracy ± 3 µ m: 0.001 µ m, accuracy ± 5 µ m: 0.010 µ m
Clock frequency
d 16 MHz
Calculation time tcal
d 5 µ s
Electrical connection
Separate adapter cable connectable at both ends of mounting block
Cable length
d 100 m ( with HEIDENHAIN cable) , clock frequency d 8 MHz
Power supply
3.6 to 14 V DC
Power consumption ( max.)
At 14 V: d 1.3 W; at 3.6 V: d 1.1 W
Power consumption ( typical)
At 5 V: 0.7 W ( without load)
Traversing speed
d 180 m/ min
Required moving force
d 4 N
Vibration 55 to 2 000 Hz
affecting the
Shock 11 ms
Acceleration
Housing: d 200 m/ s2 ( EN 60 068-2-6)
Scanning unit: d 200 m/ s2 ( EN 60 068-2-6)
d 300 m/ s2 ( EN 60 068-2-27)
d 100 m/ s2 in measuring direction
Operating temperature 0 ° C to 50 ° C
Protection EN 60 5292)
IP 53 when installed according to instructions in the brochure, IP 64 with sealing air from DA 400
Weight 0.55 kg + 2.9 kg/ m measuring length
* Please select when ordering
1) Further tolerances may occur in the subsequent electronics after the position value comparison ( contact the manufacturer of the subsequent electronics) / 2) In the application the LC must be protected from the intrusion of particles and liquids
Another Type :
= = = = = = = = =
LC 405-Functional Safety , LC 405 , LC 403-Predecessor ,
LC 105-Functional Safety , LC 105 , LC 103-Predecessor ,
LC 200 , LF 485 , LF185 , LS400 .
= = = = = = = = = = = = = = = = = = = = = =
CALL : PT DWI SUBUR MAKMUR
Jakarta - Indonesia
Telp : 021 47869642 , 47881968 , 4759101
Fax : 021 4719009
Email : dsm@ indo.net.id
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Tampilkan Lebih Banyak