Detail HEIDENHAIN LC 403-Predecessor
pecifications LC 483 LC 493 F LC 493 M
Measuring standard
Coefficient of linear expansion
DIADUR glass scale with absolute track and incremental track
± therm H 8 x 10-6 K-1 ( mounting type I) ; with mounting spar: ± therm H 9 x 10-6 K-1 ( mounting type II)
Accuracy grade*
± 3 µ m; ± 5 µ m
Measuring length ML* in mm
Mounting spar* or clamping elements* optional
70, 120, 170, 220, 270, 320, 370, 420, 470, 520, 570, 620, 670, 720,
770, 820, 870, 920, 1020, 1140, 1240
Mounting spar* or clamping elements* required
1 340 1 440 1 540 1 640 1 740 1 840 2 040
Absolute position values*
EnDat 2.2
Ordering designation EnDat 02
Fanuc 02 serial interface
Mitsubishi high speed serial interface, Mit 02-4 or Mitsu 01
Resolution
Accuracy ± 3 µ m
Accuracy ± 5 µ m
0.005 µ m
0.01 µ m
0.01 µ m
0.05 µ m
Calculation time tcal
EnDat 2.1 command set
EnDat 2.2 command set
< 1 ms
d 5 µ –
–
Incremental signals
1 VPP1)
–
Grating period/ signal period
20 µ m
–
Cutoff frequency – 3dB
e 150 kHz
–
Power supply Without load
3.6 to 5.25 V/ < 300 mA
Electrical connection
Separate adapter cable ( 1 m/ 3 m/ 6 m/ 9 m) connectable to mounting block
Cable length2)
d 150 m; depending on the interface and subsequent electronics
d 30 m
d 20 m
Traversing speed d 180 m/ min
Required moving force d 5 N
Vibration 55 to 2 000 Hz
Shock 11 ms
Acceleration
Without mounting spar: d 100 m/ s2 ( EN 60 068-2-6)
With mounting spar and cable outlet at right/ left: d 200 m/ s2/ 100 m/ s2 ( EN 60 068-2-6)
d 300 m/ s2 ( EN 60 068-2-27)
d 100 m/ s2 in measuring direction
Operating temperature 0 ° C to 50 ° C
Protection EN 60 529
IP 53 when mounted according to the instructions and mounting information
IP 64 if compressed air is connected via DA 400
Weight
Encoder: 0.2 kg + 0.5 kg/ m measuring length, mounting spar: 0.9 kg/ m
* Please select when ordering
1) Depending on the adapter cable 2) With HEIDENHAIN cable
Mounting type I = Without mounting spar
Mounting type II = Mounting with mounting spar
ANOTHER TYPE :
= = = = = = = = = =
LC 405 - Functional Safety , LC 405 , LC 403 Predecessor ,
LC 105 - Functional Safety , LC 105 , LC 103 Predecessor
LC 200 , LF 485
= = = = = = = = = =
Call : PT DWI SUBUR MAKMUR
jakarta- Indonesia
Telp : 021 47869642, 47881968, 4759101
fax : 021 4719009
email : dsm@ indo.net.id
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Tampilkan Lebih Banyak