Detail HEIDENHAIN LC 200
Specifications LC 211 LC 281
Measuring standard
Coefficient of linear expansion
METALLUR steel scale tape with absolute track and incremental track, grating period 40 µ m
Same as machine base ( e.g. Þ therm 10 x 10-6 K-1 for cast iron)
Accuracy grade
± 5 µ m
Measuring length ML*
in mm
4240 mm to 28040 mm in 200 mm steps
Kit with single-section METALLUR steel scale tape and housing section lengths
Absolute position values
EnDat 2.21)
Ordering designation
EnDat 22
EnDat 02
Resolution
0.010 µ m
Clock frequency
d 16 MHz
d 2 MHz
Calculation time tcal
d 5 µ s
Incremental signals
–
1 VPP
Signal period
–
40 µ m
Cutoff frequency – 3 dB
–
e 250 kHz
Electrical connection
Separate adapter cable ( 1 m/ 3 m/ 6 m/ 9 m) connectable on both sides to mounting block
Cable length
( with HEIDENHAIN cable)
d 100 m ( at clock frequency d 8 MHz)
d 150 m
Power supply
3.6 to 14 V DC
Power consumption ( max.)
At 14 V: d 1.5 W
At 3.6 V: d 1.1 W
Current consumption ( typical)
At 5 V: 225 mA ( without load)
Traversing speed
d 120 m/ min ( d 180 m/ min upon request)
Required moving force
d 15 N
Vibration 55 to 2000 Hz
affecting the
Shock 11 ms
Acceleration
Housing: 200 m/ s2 ( EN 60 068-2-6)
Scanning unit: 300 m/ s2 ( EN 60 068-2-6)
d 300 m/ s2 ( EN 60 068-2-27)
d 100 m/ s2 in measuring direction
Operating temperature
0 ° C to 50 ° C
Protection EN 60 529
IP 53 when installed according to mounting instructions, IP 64 with sealing air from DA 400
Weight
1.3 kg + 3.6 kg/ m measuring length
Another Type :
= = = = = = = = =
LC 405-Functional safety , LC 405, LC 403-Predecessor ,
LC 105 Functional safety , LC 105 , LC103 Functional Safety
LC 200 , LF 485 , LF 185 , LS 400 , LB382 Single Section
LB 382 Multi Section
= = = = = = = = = = = = =
CALL : PT DWI SUBUR MAKMUR
Jakarta Indonesia
Telp : 021 47869642, 47881968, 4759101
Fax : 021 4719009
Email : dsm@ indo.net.id
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Tampilkan Lebih Banyak